TR281E
Electro dynamic prime mover
Frequency and amplitude can be varied
Preprogrammed Test cycle
Specification
Parameter
Unit
Minimum
Maximum
Remarks
Stroke
mm
0.02
2
Conitinously variable
Frequency
Hz
1
200
In steps of 1 Hz.
Test load
N
1
10
Dead weight loading in 1 N steps
Frictional force
N
-10
+10
Temperature
o
C
Ambient
120
Specimen Size
Plate
mm
10 x 10 x 4
Fixed specimen
Ball dia
mm
6 and 10
Point contact
Cylinder/Pin
dia x L mm
6 x 16
Line contact
Pin
dia x L mm
10 x 6
Area contact